XTR: How to access multiple nodes via product GUIs when all nodes have the same name or no EXPAND links exist between systems

XTR: How to access multiple nodes via product GUIs when all nodes have the same name or no EXPAND links exist between systems

This will allow the user to access all systems via the GUI products.  The user  must make the following modification to the TRACL file in the XTR installation on each system:

1. Make sure that there is a TR_INSTALLATION entry for each system to be accessed via a GUI
2. Add a dummy node name at the end of each TR_INSTALLATION line.  This dummy node name should be unique for each system.


Example:

TR_INSTALLATION \MYSYS.$DATA38.XYGATETR 10.180.1.5 12501  \DUMMY1
TR_INSTALLATION \MYSYS.$DATA38.XYGATETR 10.128.21.3 12501  \DUMMY2