XMA: XUA Mover abends when processing XUA protocol types

XMA: XUA Mover abends when processing XUA protocol types

Solution: Upgrade to XMA 2.45 or other

Cause: XMA 2.43 and older could not properly extract protocol from XUA audits

The issue is addressed in XMA Version 2.45

* ITID 245-13395 Update to Extract protocol type from XYGATE User Authentication (XUA) Audits

    Description: Protocol type is now available from XUA audits. The XMA mover was updated to extract the protocol type from XUA audits.

    Summary: The XUA session type will be mapped in the SESSIONNAME column of AUDSESS.


If you are unable to locate the solution needed or if you need additional assistance please Click Here to open a case from our Customer Care Portal.


    • Related Articles

    • XMA: Newly added EPS Mover abends and will not start

      If a newly added EPS mover is abending and will not start steps should be taken to ensure both the UALOGD and UALOGD0 can be accessed by Merged Audit. Please check both files have appropriate guardian security and that there is no safeguard ACL ...
    • XMA: Safeguard Mover Abends After Pathway Reset and Daylight Savings has ended

      Use the following steps in order to resolve this condition: You will need the last record processed by the Safeguard mover. TACL> VOLUME $<XMA Database Volume/Subvolume> TACL> SQLCI >> SELECT LASTRECORDGMTTSTMP FROM SFGST BROWSE ACCESS; SQL ...
    • XMA: Saveabend files are not being created by mover abends

      1. Does the security of the XYGATEMA (XMA) installation disk volume or subvolume allow CREATE access to the XMA installation owner? Check for any Safeguard volume or subvolume ACLs or XYGATEOS rules that prevent WRITE or CREATE access for the XMA ...
    • XMA: Measure Mover Keeps Abending

      Is XYPRO SecurityOne installed? The Measure mover is not designed to collect system performance metrics. It is designed to only capture process information for the XYGATE SecurityOne WHO Resolver. The MEASURE mover collects information regarding ...
    • XMA: How to force a Mover to read data from the first file in the products Audit Pool

      Deleting and re-adding the mover is the only way to get the Safeguard mover to read the product audit pool records from the beginning if re-populating an XMA database that was re-partitioned and data was lost. Deleting the Mover: Using XMA_MANAGER ...