XMA: The message "System not licensed for XYGATE-MA" is displayed when running XMA_MANAGER during a new XMA install

XMA: The message "System not licensed for XYGATE-MA" is displayed when running XMA_MANAGER during a new XMA install

1. Run LICCHK from the XYGATEMA subvolume to ensure that the license is valid.

   Example:

   a. VOLUME $SYSTEM.XYGATEMA
   b. RUN LICCHK P28F001


2. If the license is good, check to see fi the FILTERS file can be compiled.  From the XYGATEMA
    subvolume:

   FILTCOMP COMPILEFILTERS
  
  The FILTERS file should compile with no errors

3. If the license is good and the FILTERS file compiles error-free, check the XYGATEMA subvolume for
   both P28F001 and P99F001 license files.   If both exist, rename the  P99F001 license file to a different
   name and run XMA_MANAGER again.  


If you are unable to locate the solution needed or if you need additional assistance please Click Here to open a case from our Customer Care Portal.

    • Related Articles

    • XYGATE License Expiration

      XYGATEAC Product license file: P06F001 Macro to install license: XAC_INSTALL_LICENSE Expiration behavior: The DBSO program reads the license file on startup to determine when the license will expire. The license is checked once each day from then on ...
    • XMA-XTR: Can XMA/XTR run on a system where SQL/MP is not licensed?

      XMA and XTR are allowed on systems that are not licensed for SQL/MP. ???????Important! If an HPE Non-Stop Server is not licensed for SQL by HPE, XMA is compiled with a runtime license so that you can use it with just a few limitations. The only ...
    • XMA: Procedure to stop XYGATE Merged Audit when changing system time

      The correct procedure is to stop all pathway serverclasses, including XMA movers and admin servers (HKEEPER, SLSENDER, etc.) using XMA_MANAGER. >run xma install >xma_manager XYGATEMA Management Main Menu v2.60 * * * * * * * * * * * * * * * * * * * 1: ...
    • XMA: xma_manager Check_SQLCompileNeeded

      Run the XMA_SQLCOMPALL macro to compile XMA object files. This problem arises when XMA object files have not been recompiled more 7 days after product installation. The solution is to recompile the SQL objects using the XMA_SQLCOMPALL macro. From the ...
    • XMA: Updating INSTALL.IPADDRESS

      The reported IP address is populated during install of XMA and needs to be changed manually if XMA is not being re-installed 1) Attach the XMA segment and run the XMA_DBVOLUME command 2) Enter SQLCI 3) Run the following query to change the IP ...